Цепь 115 в соответствии со стандартом V.24
Цепь 115, в соответствии со стандартом V.24
Цепь 115, в соответствии со стандартом V.24 - название и назначение этой цепи описано в стандарте V.24 для DTE следующим образом:
“Receiver signal element timing (DCE).
Signals on this circuit provide the DTE with receiver signal element timing information. The condition of this circuit shall be ON and OFF for nominally equal periods of time, and a transition from ON to OFF condition shall nominally indicate the centre of each signal element on circuit 104.
Where variable receiver signal element timing is required, the change to a different rate shall occur while this circuit is in the OFF condition. The new rate shall be an integer multiple or fraction of the old rate.
Where it is required to temporarily halt data reception, this circuit may be held in the OFF condition for a limited period of time. The maximum permissible duration of this condition is for further study.
The duration of the OFF condition shall be an integer multiple of the length of a signal element before halting the signal. Signalling on this circuit may then be resumed at the same rate or at a different rate, as specified above.
Where also character or 8-bit byte timing is provided using circuit 131 – Received character timing (DCE source), the change to a different rate on circuit 115 shall occur during the OFF condition that precedes the OFF-to-ON transition which indicates the first bit of a new character or 8-bit byte”.
Группа сигналов и направление этого сигнала относительно DCE следующие: синхронизация, к DCE,вход.
Назначение цепи: Сигнал синхронизации приемника.
Сигнал синхронизации, который использует DCE для приема данных по цепи RXD, (цепь 104). Переход от ON в состояние OFF номинально должен указывать на центр каждого элемента сигнала передаваемого по цепи 104.
Например, смотрите рисунок: